  1. Fire Alarm devices for machine-less elevator and machine room …

    Sep 12, 2024 · Scenario below is for 2 or 3 levels elevator. Machine-less elevator (no equipment room, equipment in hoist-way): Smoke detectors outside each elevator lobby floor for recall protocol. …

  2. Elevator Recall Smoke Detectors | Information by Electrical ...

    May 23, 2005 · Re: Elevator Recall Smoke Detectors According to the NFPA 72 2002 Edition the section 6.15 applies. 1) & 2) 6.15.3.5 A lobby smoke detector shall be located on the ceiling within 21 feet of …

  3. How To Perform Elevator Recall... | Information by Electrical ...

    Jan 16, 2008 · A elevator lobby smoke detector activates "Phase 1" elevator recall. The elevator control panel handles the hard stuff but it will cause the "Fireman's Hat" lamp in the elevator to turn on steady.

  4. Elevators | Information by Electrical Professionals for Electrical ...

    Dec 12, 2014 · What type of electrical and fire alarm is required by NEC and elevator code. I know elevator contractors always want extra receptacles and lights. I was wondering what is the minimum …

  5. Elevator Recall Relays Wiring | Information by Electrical Professionals ...

    Dec 9, 2024 · The panel is going to have functions that assign inputs and outputs. So function F1 for primary recall, will have all the elevator lobby smoke detectors EXCEPT for the primary floor elevator …

  6. Elevator Lobby (sill) lighting | Information by Electrical ...

    Oct 4, 2010 · An elevator rep is indicating this requirement prevents the lobby lighting from being switched. Can anybody weigh in on this, or clarify what exactly "elevator is in service" means?

  7. elevator recall wiring conventional fa system | Information by ...

    Oct 17, 2013 · For one, only the elevator lobby, shaft and equipment room smoke detectors are allowed to recall the elevator. Depending on how many zones your panel is and how many floors the building …

  8. Fire Alarm- Elevator Recall required for All Elevators?

    Dec 2, 2020 · I have a large high end residential project, Type R-3, that has an elevator. The state code does not require a fire alarm system for this type of occupancy, but since there is the elevator, does …

  9. Fire Alarm/Elevator Recall/Hat/Shunt Wiring

    Mar 3, 2010 · When any heat detector is activated, primary elevator power shall be shut down via a shunt trip breaker supplying the elevator equipment. The shunt trip power must be 120VAC and must …

  10. Elevator lighting | Information by Electrical Professionals for ...

    May 26, 2012 · Your best bet would be to check the elevator codes for your state. I highly doubt that anything less than 24/7 would be allowed in WI. As they do require X # of foot candles at the floor in …